What a 9/12 pitch means
The roof goes up 9 inches for every 12 inches it runs level. That works out to an angle of 36.87 degrees, a slope of 75.0 percent, and a pitch multiplier of 1.250. It is 3.2 degrees steeper than an 8/12 roof.
A 9/12 roof is in the conventional range for houses. Over the same house, it has 25.0 percent more surface than a flat roof.
Where you see 9/12 roofs
9/12 suits two-story traditional houses, cottages and colonial revival homes with tall front gables. In old carpentry terms it is a three-eighths pitch.
Rafter lengths at 9/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 7' 6" | 4' 6" | 6 ft |
| 16 ft | 10' 0" | 6' 0" | 8 ft |
| 20 ft | 12' 6" | 7' 6" | 10 ft |
| 24 ft | 15' 0" | 9' 0" | 12 ft |
| 28 ft | 17' 6" | 10' 6" | 14 ft |
| 32 ft | 20' 0" | 12' 0" | 16 ft |
| 36 ft | 22' 6" | 13' 6" | 18 ft |
| 40 ft | 25' 0" | 15' 0" | 20 ft |
Roof area at 9/12
Multiply the flat area the roof covers, overhangs included, by 1.250. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,250 sq ft | 12.5 |
| 1,500 sq ft | 1,875 sq ft | 18.8 |
| 2,000 sq ft | 2,500 sq ft | 25.0 |
| 2,500 sq ft | 3,125 sq ft | 31.3 |
| 3,000 sq ft | 3,750 sq ft | 37.5 |
Roofing that works at 9/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 9/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes |
| Clay or concrete tile | 2 1/2 in 12 | Yes |
| Wood shingles or shakes | 3 in 12 | Yes |
| Metal roof shingles | 3 in 12 | Yes |
| Slate | 4 in 12 | Yes |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Yes |
The roofing rules match 8/12: one layer of underlayment, and the longer ice barrier where the code requires one. Every roofing type in the table is allowed.
Underlayment and ice barrier at 9/12
At 9/12 one layer of underlayment is enough under shingles and tile.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. At 9/12 it must also reach at least 36 inches up the slope from the eave, whichever is farther.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 36 in |
| 12 in | 45 in |
| 24 in | 60 in |
Attic space at 9/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 108' 0" | 10' 8" | 5' 4" |
| 28 ft | 126' 0" | 14' 8" | 9' 4" |
| 32 ft | 144' 0" | 18' 8" | 13' 4" |
| 36 ft | 162' 0" | 22' 8" | 17' 4" |
| 40 ft | 180' 0" | 26' 8" | 21' 4" |
The ridge reaches 5 feet on a house about 13 feet wide, and 7 feet on one about 19 feet wide.
Working on a 9/12 roof
On a 9/12 roof even the step from the ladder to the first plank takes care, so crews set the eave staging and anchors before anyone climbs onto the roof. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts anything over 4 in 12 as a steep roof, so workers 6 feet or more up need guardrails with toeboards, safety nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 0.9 degrees gentler.
More about 9/12 roofs
9/12 is a 3-4-5 triangle. The rise is three quarters of the run, so every 12 inches of run takes exactly 15 inches of rafter, and the pitch multiplier is a round 1.25. That makes it one of the easiest pitches to check with a tape measure.
Nearby pitches
Compare with the 8/12 roof pitch and 10/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 9/12 roof pitch in degrees?
36.87 degrees, which is a 75.0 percent slope.
What is the pitch multiplier for a 9/12 roof?
1.250. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 9/12?
About 15' 0" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 9' 0" above the top of the wall.
Can you put asphalt shingles on a 9/12 roof?
Yes. A 9/12 roof is above the 4 in 12 mark, so asphalt shingles go on with standard single underlayment.
Is a 9/12 roof walkable?
As a rule of thumb, footing gets poor at 9/12. Roof jacks or a harness are normal at this pitch. Any roof is dangerous when wet.
Why is the 9/12 pitch multiplier exactly 1.25?
Because 9, 12 and 15 make a right triangle, the same shape as 3, 4 and 5. A rafter that climbs 9 inches over 12 inches of run is 15 inches long, and 15 divided by 12 is 1.25.
Is 9/12 a steep roof?
Yes, by every measure here. OSHA calls anything over 4/12 a steep roof, roofers work a 9/12 roof from roof jacks, and HomeAdvisor notes higher labor costs on roofs steeper than 6/12.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.