What an 8/12 pitch means
The roof goes up 8 inches for every 12 inches it runs level. That works out to an angle of 33.69 degrees, a slope of 66.7 percent, and a pitch multiplier of 1.202. It is 3.4 degrees steeper than a 7/12 roof.
An 8/12 roof is in the conventional range for houses. Over the same house, it has 20.2 percent more surface than a flat roof.
Where you see 8/12 roofs
8/12 is common on two-story colonial-style houses and on newer homes with steeper front gables.
Rafter lengths at 8/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 7' 2 9/16" | 4' 0" | 6 ft |
| 16 ft | 9' 7 3/8" | 5' 4" | 8 ft |
| 20 ft | 12' 0 1/4" | 6' 8" | 10 ft |
| 24 ft | 14' 5 1/16" | 8' 0" | 12 ft |
| 28 ft | 16' 9 15/16" | 9' 4" | 14 ft |
| 32 ft | 19' 2 3/4" | 10' 8" | 16 ft |
| 36 ft | 21' 7 5/8" | 12' 0" | 18 ft |
| 40 ft | 24' 0 7/16" | 13' 4" | 20 ft |
Roof area at 8/12
Multiply the flat area the roof covers, overhangs included, by 1.202. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,202 sq ft | 12.0 |
| 1,500 sq ft | 1,803 sq ft | 18.0 |
| 2,000 sq ft | 2,404 sq ft | 24.0 |
| 2,500 sq ft | 3,005 sq ft | 30.0 |
| 3,000 sq ft | 3,606 sq ft | 36.1 |
Roofing that works at 8/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On an 8/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes |
| Clay or concrete tile | 2 1/2 in 12 | Yes |
| Wood shingles or shakes | 3 in 12 | Yes |
| Metal roof shingles | 3 in 12 | Yes |
| Slate | 4 in 12 | Yes |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Yes |
8/12 is where the 2021 International Residential Code adds a second ice barrier rule. In places with a history of ice forming along the eaves, the ice barrier has to reach 24 inches inside the outside wall, and on roofs of 8/12 or steeper it must also run at least 36 inches up the slope from the eave.
Underlayment and ice barrier at 8/12
At 8/12 one layer of underlayment is enough under shingles and tile.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. At 8/12 it must also reach at least 36 inches up the slope from the eave, whichever is farther.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 36 in |
| 12 in | 43 in |
| 24 in | 58 in |
Attic space at 8/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 96' 0" | 9' 0" | 3' 0" |
| 28 ft | 112' 0" | 13' 0" | 7' 0" |
| 32 ft | 128' 0" | 17' 0" | 11' 0" |
| 36 ft | 144' 0" | 21' 0" | 15' 0" |
| 40 ft | 160' 0" | 25' 0" | 19' 0" |
The ridge reaches 5 feet on a house about 15 feet wide, and 7 feet on one about 21 feet wide.
Working on an 8/12 roof
Few people can stand on an 8/12 roof without support. The work happens from planks on roof jacks and from roof ladders hooked over the ridge, with each worker in a harness. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts anything over 4 in 12 as a steep roof, so workers 6 feet or more up need guardrails with toeboards, safety nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 4.1 degrees gentler.
More about 8/12 roofs
The 36 inch ice barrier rule matters most on houses with short overhangs. With a 12 inch overhang, the 24 inch rule already carries the ice barrier about 43 inches up an 8/12 slope. With no overhang it reaches only about 29 inches, and the steep roof rule adds the rest.
Nearby pitches
Compare with the 7/12 roof pitch and 9/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is an 8/12 roof pitch in degrees?
33.69 degrees, which is a 66.7 percent slope.
What is the pitch multiplier for an 8/12 roof?
1.202. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 8/12?
About 14' 5 1/16" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 8' 0" above the top of the wall.
Can you put asphalt shingles on an 8/12 roof?
Yes. An 8/12 roof is above the 4 in 12 mark, so asphalt shingles go on with standard single underlayment.
Is an 8/12 roof walkable?
As a rule of thumb, footing gets poor at 8/12. Roof jacks or a harness are normal at this pitch. Any roof is dangerous when wet.
How far up does ice barrier go on an 8/12 roof?
Where the code requires an ice barrier, it runs from the eave to at least 24 inches inside the outside wall, and on an 8/12 or steeper roof it must also cover at least 36 inches measured up the slope from the eave. Whichever reaches farther is the one to follow.
What is an 8/12 roof in old carpentry terms?
A third pitch. Old books give pitch as the rise over the full span, and an 8/12 roof rises a third of its span.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof