What a 7/12 pitch means
The roof goes up 7 inches for every 12 inches it runs level. That works out to an angle of 30.26 degrees, a slope of 58.3 percent, and a pitch multiplier of 1.158. It is 3.7 degrees steeper than a 6/12 roof.
A 7/12 roof is in the conventional range for houses. Over the same house, it has 15.8 percent more surface than a flat roof.
Where you see 7/12 roofs
7/12 is a common choice on two-story houses and newer homes, where a slightly steeper roof adds height to the front of the house without the cost of a very steep one.
Rafter lengths at 7/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 6' 11 3/8" | 3' 6" | 6 ft |
| 16 ft | 9' 3 1/8" | 4' 8" | 8 ft |
| 20 ft | 11' 6 15/16" | 5' 10" | 10 ft |
| 24 ft | 13' 10 11/16" | 7' 0" | 12 ft |
| 28 ft | 16' 2 1/2" | 8' 2" | 14 ft |
| 32 ft | 18' 6 1/4" | 9' 4" | 16 ft |
| 36 ft | 20' 10 1/16" | 10' 6" | 18 ft |
| 40 ft | 23' 1 7/8" | 11' 8" | 20 ft |
Roof area at 7/12
Multiply the flat area the roof covers, overhangs included, by 1.158. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,158 sq ft | 11.6 |
| 1,500 sq ft | 1,737 sq ft | 17.4 |
| 2,000 sq ft | 2,315 sq ft | 23.2 |
| 2,500 sq ft | 2,894 sq ft | 28.9 |
| 3,000 sq ft | 3,473 sq ft | 34.7 |
Roofing that works at 7/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 7/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes |
| Clay or concrete tile | 2 1/2 in 12 | Yes |
| Wood shingles or shakes | 3 in 12 | Yes |
| Metal roof shingles | 3 in 12 | Yes |
| Slate | 4 in 12 | Yes |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Yes |
Every roofing type in the table is allowed. 7/12 is the first whole-number pitch past the line where HomeAdvisor says labor costs go up, and the last one before the code adds its longer ice barrier rule at 8/12.
Underlayment and ice barrier at 7/12
At 7/12 one layer of underlayment is enough under shingles and tile.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. The extra 36 inch rule for steep roofs starts at 8/12.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 28 in |
| 12 in | 42 in |
| 24 in | 56 in |
Attic space at 7/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 84' 0" | 6' 10 5/16" | None |
| 28 ft | 98' 0" | 10' 10 5/16" | 4' 0" |
| 32 ft | 112' 0" | 14' 10 5/16" | 8' 0" |
| 36 ft | 126' 0" | 18' 10 5/16" | 12' 0" |
| 40 ft | 140' 0" | 22' 10 5/16" | 16' 0" |
The ridge reaches 5 feet on a house about 17 feet wide, and 7 feet on one about 24 feet wide.
Working on a 7/12 roof
Past 6/12 the footing changes. On a 7/12 roof, crews usually set roof jacks with planks along the eave and work from them, tied off to an anchor at the ridge. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts anything over 4 in 12 as a steep roof, so workers 6 feet or more up need guardrails with toeboards, safety nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 7.5 degrees gentler.
More about 7/12 roofs
A 30 degree roof would be 6.93 in 12, so 7/12 is the whole-number pitch closest to 30 degrees. Moving up from 6/12 to 7/12 adds about 3.5 percent more roof surface over the same house, which shows up in the shingle and underlayment order. On a framing square, carpenters mark 7/12 cuts with the 12 inch mark on the body and the 7 inch mark on the tongue.
Nearby pitches
Compare with the 6/12 roof pitch and 8/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 7/12 roof pitch in degrees?
30.26 degrees, which is a 58.3 percent slope.
What is the pitch multiplier for a 7/12 roof?
1.158. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 7/12?
About 13' 10 11/16" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 7' 0" above the top of the wall.
Can you put asphalt shingles on a 7/12 roof?
Yes. A 7/12 roof is above the 4 in 12 mark, so asphalt shingles go on with standard single underlayment.
Is a 7/12 roof walkable?
As a rule of thumb, footing gets poor at 7/12. Roof jacks or a harness are normal at this pitch. Any roof is dangerous when wet.
Is 7/12 the same as a 30 degree roof?
Very close. 7/12 is 30.26 degrees. An exact 30 degree roof would be 6.93 in 12, so 7/12 is the nearest whole-number pitch.
Does a 7/12 roof cost more to replace?
Usually a little. HomeAdvisor notes higher labor costs on roofs steeper than 6/12, and a 7/12 roof has about 16 percent more surface than the ground it covers.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.