What a 6/12 pitch means
The roof goes up 6 inches for every 12 inches it runs level. That works out to an angle of 26.57 degrees, a slope of 50.0 percent, and a pitch multiplier of 1.118. It is 3.9 degrees steeper than a 5/12 roof.
A 6/12 roof is in the conventional range for houses. Over the same house, it has 11.8 percent more surface than a flat roof.
Where you see 6/12 roofs
6/12 is a very common pitch on houses, from one-story ranches to two-story homes, and it is the starting example in this site's roof calculators. The roof rises exactly half as far as it runs, a 50 percent slope.
Rafter lengths at 6/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 6' 8 1/2" | 3' 0" | 6 ft |
| 16 ft | 8' 11 5/16" | 4' 0" | 8 ft |
| 20 ft | 11' 2 3/16" | 5' 0" | 10 ft |
| 24 ft | 13' 5" | 6' 0" | 12 ft |
| 28 ft | 15' 7 13/16" | 7' 0" | 14 ft |
| 32 ft | 17' 10 11/16" | 8' 0" | 16 ft |
| 36 ft | 20' 1 1/2" | 9' 0" | 18 ft |
| 40 ft | 22' 4 5/16" | 10' 0" | 20 ft |
Roof area at 6/12
Multiply the flat area the roof covers, overhangs included, by 1.118. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,118 sq ft | 11.2 |
| 1,500 sq ft | 1,677 sq ft | 16.8 |
| 2,000 sq ft | 2,236 sq ft | 22.4 |
| 2,500 sq ft | 2,795 sq ft | 28.0 |
| 3,000 sq ft | 3,354 sq ft | 33.5 |
Roofing that works at 6/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 6/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes |
| Clay or concrete tile | 2 1/2 in 12 | Yes |
| Wood shingles or shakes | 3 in 12 | Yes |
| Metal roof shingles | 3 in 12 | Yes |
| Slate | 4 in 12 | Yes |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Yes |
Shingles, tile, slate, wood and every kind of metal roof are allowed at 6/12. It is also the steepest pitch that still prices as a standard roof: HomeAdvisor notes that labor costs go up on roofs steeper than 6/12.
Underlayment and ice barrier at 6/12
At 6/12 one layer of underlayment is enough under shingles and tile.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. The extra 36 inch rule for steep roofs starts at 8/12.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 27 in |
| 12 in | 40 in |
| 24 in | 54 in |
Attic space at 6/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 72' 0" | 4' 0" | None |
| 28 ft | 84' 0" | 8' 0" | None |
| 32 ft | 96' 0" | 12' 0" | 4' 0" |
| 36 ft | 108' 0" | 16' 0" | 8' 0" |
| 40 ft | 120' 0" | 20' 0" | 12' 0" |
The ridge reaches 5 feet on a house about 20 feet wide, and 7 feet on one about 28 feet wide.
Working on a 6/12 roof
6/12 is about the steepest pitch most roofers will walk upright without roof jacks. Soft soles and a clean, dry surface matter, because loose granules on new shingles roll underfoot. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts anything over 4 in 12 as a steep roof, so workers 6 feet or more up need guardrails with toeboards, safety nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 11.2 degrees gentler.
More about 6/12 roofs
In old carpentry books, pitch was the rise over the full span, and by that measure 6/12 is a quarter pitch. Over a 24 foot wide house the ridge sits 6 feet above the ceiling joists, so no part of that attic reaches the 7 feet of headroom the code wants over at least half of a room's floor.
Nearby pitches
Compare with the 5/12 roof pitch and 7/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 6/12 roof pitch in degrees?
26.57 degrees, which is a 50.0 percent slope.
What is the pitch multiplier for a 6/12 roof?
1.118. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 6/12?
About 13' 5" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 6' 0" above the top of the wall.
Can you put asphalt shingles on a 6/12 roof?
Yes. A 6/12 roof is above the 4 in 12 mark, so asphalt shingles go on with standard single underlayment.
Is a 6/12 roof walkable?
As a rule of thumb, roofers treat a 6/12 roof as walkable with care. Any roof is dangerous when wet.
What is a 6/12 roof in old carpentry terms?
A quarter pitch. Old books give pitch as the rise over the full span, and a roof that rises 6 inches for every 12 inches of run rises a quarter of the span.
Does a 6/12 roof cost more to replace than a lower one?
Not for steepness alone. HomeAdvisor notes that labor costs go up on roofs steeper than 6/12, so 6/12 is usually priced as a standard roof. It does have about 12 percent more surface than the ground it covers, which adds material.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.