What a 2/12 pitch means
The roof goes up 2 inches for every 12 inches it runs level. That works out to an angle of 9.46 degrees, a slope of 16.7 percent, and a pitch multiplier of 1.014. It is 4.7 degrees steeper than a 1/12 roof.
A 2/12 roof is a low slope roof. It sheds water more slowly than a typical house roof, so the building code asks for extra protection under shingles. Over the same house, it has 1.4 percent more surface than a flat roof.
Where you see 2/12 roofs
A 2/12 roof is common over porches, patio covers, sunrooms and back additions that tie in under the eaves of the main roof, where a steeper slope would run into the windows above. Some mid-century modern houses use 2/12 for wide, low gables.
Rafter lengths at 2/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 6' 1" | 1' 0" | 6 ft |
| 16 ft | 8' 1 5/16" | 1' 4" | 8 ft |
| 20 ft | 10' 1 5/8" | 1' 8" | 10 ft |
| 24 ft | 12' 2" | 2' 0" | 12 ft |
| 28 ft | 14' 2 5/16" | 2' 4" | 14 ft |
| 32 ft | 16' 2 5/8" | 2' 8" | 16 ft |
| 36 ft | 18' 3" | 3' 0" | 18 ft |
| 40 ft | 20' 3 5/16" | 3' 4" | 20 ft |
Roof area at 2/12
Multiply the flat area the roof covers, overhangs included, by 1.014. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,014 sq ft | 10.1 |
| 1,500 sq ft | 1,521 sq ft | 15.2 |
| 2,000 sq ft | 2,028 sq ft | 20.3 |
| 2,500 sq ft | 2,534 sq ft | 25.3 |
| 3,000 sq ft | 3,041 sq ft | 30.4 |
Roofing that works at 2/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 2/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes, with double underlayment |
| Clay or concrete tile | 2 1/2 in 12 | No |
| Wood shingles or shakes | 3 in 12 | No |
| Metal roof shingles | 3 in 12 | No |
| Slate | 4 in 12 | No |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Only with lap sealant |
2/12 is the lowest pitch where the code allows asphalt shingles at all, and only over a double layer of underlayment. Clay and concrete tile need 2 1/2 in 12, and wood shingles, wood shakes and metal roof shingles need 3 in 12, so none of them can go on a 2/12 roof. Lapped metal panels need sealed laps until 3/12. Standing seam metal and membranes are well within their limits.
Underlayment and ice barrier at 2/12
Below 4/12 the code wants two layers under asphalt shingles: a 19 inch strip along the eave, then 36 inch wide sheets, each lapping the one below by 19 inches, so every spot is covered twice. End laps are 4 inches, staggered 6 feet apart. Tile needs the double layer below 4/12 too.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. The extra 36 inch rule for steep roofs starts at 8/12.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 24 in |
| 12 in | 36 in |
| 24 in | 49 in |
Attic space at 2/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 24' 0" | None | None |
| 28 ft | 28' 0" | None | None |
| 32 ft | 32' 0" | None | None |
| 36 ft | 36' 0" | None | None |
| 40 ft | 40' 0" | None | None |
It takes a house about 84 feet wide for the ridge to reach 7 feet, so on an ordinary house this attic is storage or crawl space.
Working on a 2/12 roof
You can walk a 2/12 roof about as easily as a sloped driveway. Water and frost linger on it longer than on a steeper roof, though, and wet underlayment or membrane is slick. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts a roof of 4 in 12 or less as low-slope, so roofing crews here may use a warning line with a safety monitor, as well as guardrails, nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 28.3 degrees gentler.
More about 2/12 roofs
On a slope this shallow, wind-driven rain and melting ice can be pushed back up under shingle laps, and the double underlayment is the code answer to that. The shingle maker instructions can ask for more than the code does, so read them before you buy. Old carpentry books, which measured rise against the full span, would call this a one-twelfth pitch.
Nearby pitches
Compare with the 1/12 roof pitch and 3/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 2/12 roof pitch in degrees?
9.46 degrees, which is a 16.7 percent slope.
What is the pitch multiplier for a 2/12 roof?
1.014. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 2/12?
About 12' 2" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 2' 0" above the top of the wall.
Can you put asphalt shingles on a 2/12 roof?
Yes, but the International Residential Code requires a double layer of underlayment on roofs from 2 in 12 up to 4 in 12. Check the shingle maker instructions as well.
Is a 2/12 roof walkable?
A 2/12 roof is easy to stand on, but the edge is still a fall hazard. Any roof is dangerous when wet.
Can you put a metal roof on a 2/12 pitch?
Yes, with the right panel. The code allows standing seam down to 1/4 in 12, and lapped panels down to 1/2 in 12 when the laps are sealed. Lapped screw-down panels without sealant need 3 in 12, and some makers ask for that anyway: Metal Sales lists 3 in 12 as the lowest pitch for its Classic Rib panel.
Can you use tile on a 2/12 roof?
No. The code sets 2 1/2 in 12 as the lowest pitch for clay and concrete tile, and asks for double underlayment under tile up to 4 in 12.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.