What a 1/12 pitch means
The roof goes up 1 inch for every 12 inches it runs level. That works out to an angle of 4.76 degrees, a slope of 8.3 percent, and a pitch multiplier of 1.003.
A 1/12 roof is nearly flat. Water drains slowly, so it needs a continuous waterproof surface rather than overlapping pieces. Over the same house, it has 0.3 percent more surface than a flat roof.
Where you see 1/12 roofs
Roofs at 1/12 are meant to look flat. You find them on modern houses, carports, sheds, and porch or patio roofs tucked under second floor windows, where there is little height to work with. Over a 12 foot run the roof drops only 1 foot, so from the street the slope is hard to see.
Rafter lengths at 1/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 6' 0 1/4" | 6" | 6 ft |
| 16 ft | 8' 0 5/16" | 8" | 8 ft |
| 20 ft | 10' 0 7/16" | 10" | 10 ft |
| 24 ft | 12' 0 1/2" | 1' 0" | 12 ft |
| 28 ft | 14' 0 9/16" | 1' 2" | 14 ft |
| 32 ft | 16' 0 11/16" | 1' 4" | 16 ft |
| 36 ft | 18' 0 3/4" | 1' 6" | 18 ft |
| 40 ft | 20' 0 13/16" | 1' 8" | 20 ft |
Roof area at 1/12
Multiply the flat area the roof covers, overhangs included, by 1.003. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,003 sq ft | 10.0 |
| 1,500 sq ft | 1,505 sq ft | 15.1 |
| 2,000 sq ft | 2,007 sq ft | 20.1 |
| 2,500 sq ft | 2,509 sq ft | 25.1 |
| 3,000 sq ft | 3,010 sq ft | 30.1 |
Roofing that works at 1/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 1/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | No |
| Clay or concrete tile | 2 1/2 in 12 | No |
| Wood shingles or shakes | 3 in 12 | No |
| Metal roof shingles | 3 in 12 | No |
| Slate | 4 in 12 | No |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Only with lap sealant |
This is the lowest pitch the code allows for mineral-surfaced roll roofing, so roll roofing sits exactly at its limit here. Asphalt shingles, tile, slate, wood shingles and metal shingles are all ruled out. Built-up roofing, modified bitumen and single-ply membranes, standing seam metal, and lapped metal panels with sealed laps are all allowed well below 1/12, which makes them the usual choices.
Underlayment and ice barrier at 1/12
Shingles and tile are not allowed at 1/12, so their underlayment rules never come up. Roll roofing, membranes and metal go over the underlayment their makers call for.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. The extra 36 inch rule for steep roofs starts at 8/12.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 24 in |
| 12 in | 36 in |
| 24 in | 48 in |
Attic space at 1/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 12' 0" | None | None |
| 28 ft | 14' 0" | None | None |
| 32 ft | 16' 0" | None | None |
| 36 ft | 18' 0" | None | None |
| 40 ft | 20' 0" | None | None |
It takes a house about 168 feet wide for the ridge to reach 7 feet, so on an ordinary house this attic is storage or crawl space.
Working on a 1/12 roof
A 1/12 roof is flat enough to stand, kneel and stack materials on, so the edge is the main danger. With no slope to warn your feet, it is easy to back up to the edge without noticing. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts a roof of 4 in 12 or less as low-slope, so roofing crews here may use a warning line with a safety monitor, as well as guardrails, nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 33.0 degrees gentler.
More about 1/12 roofs
Water leaves a roof this flat slowly, and a small sag in the framing can hold a puddle. If walls or a parapet keep water from running off the edge, the code calls for a roof drain at every low point. Snow will not slide off a 1/12 roof on its own, so it sits there until it melts.
Nearby pitches
Compare with the 2/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 1/12 roof pitch in degrees?
4.76 degrees, which is a 8.3 percent slope.
What is the pitch multiplier for a 1/12 roof?
1.003. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 1/12?
About 12' 0 1/2" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 1' 0" above the top of the wall.
Can you put asphalt shingles on a 1/12 roof?
No. The International Residential Code allows asphalt shingles only on roofs of 2 in 12 or steeper. A 1/12 roof needs a membrane, built-up roofing, roll roofing or standing seam metal.
Is a 1/12 roof walkable?
A 1/12 roof is easy to stand on, but the edge is still a fall hazard. Any roof is dangerous when wet.
Is a 1/12 roof considered flat?
It is usually called a low slope or nearly flat roof. It has enough fall to drain, and the code allows mineral-surfaced roll roofing at exactly 1 in 12, but it is too flat for asphalt shingles, which need at least 2 in 12.
What roofing goes on a 1/12 roof?
A membrane such as modified bitumen, single-ply or built-up roofing, standing seam metal, lapped metal panels with sealed laps, or mineral-surfaced roll roofing, which the code allows down to exactly 1/12. Shingles, tile, slate and wood are not allowed.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.