What a 4/12 pitch means
The roof goes up 4 inches for every 12 inches it runs level. That works out to an angle of 18.43 degrees, a slope of 33.3 percent, and a pitch multiplier of 1.054. It is 4.4 degrees steeper than a 3/12 roof.
A 4/12 roof is in the conventional range for houses. Over the same house, it has 5.4 percent more surface than a flat roof.
Where you see 4/12 roofs
A 4/12 roof is common on one-story ranch houses and hip roofs. It is the lowest pitch where a shingle roof goes on the ordinary way, with one layer of underlayment.
Rafter lengths at 4/12
Ridge to the outside of the wall on a simple gable roof. The rafter length calculator adds the overhang and takes off the ridge board.
| Building width | Rafter length | Rise at ridge | Run |
|---|---|---|---|
| 12 ft | 6' 3 7/8" | 2' 0" | 6 ft |
| 16 ft | 8' 5 3/16" | 2' 8" | 8 ft |
| 20 ft | 10' 6 1/2" | 3' 4" | 10 ft |
| 24 ft | 12' 7 13/16" | 4' 0" | 12 ft |
| 28 ft | 14' 9 1/16" | 4' 8" | 14 ft |
| 32 ft | 16' 10 3/8" | 5' 4" | 16 ft |
| 36 ft | 18' 11 11/16" | 6' 0" | 18 ft |
| 40 ft | 21' 1" | 6' 8" | 20 ft |
Roof area at 4/12
Multiply the flat area the roof covers, overhangs included, by 1.054. One roofing square is 100 square feet.
| Area covered | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,054 sq ft | 10.5 |
| 1,500 sq ft | 1,581 sq ft | 15.8 |
| 2,000 sq ft | 2,108 sq ft | 21.1 |
| 2,500 sq ft | 2,635 sq ft | 26.4 |
| 3,000 sq ft | 3,162 sq ft | 31.6 |
Roofing that works at 4/12
Lowest pitches from the International Residential Code. Local codes and maker instructions can be stricter.
| Roofing | Lowest pitch allowed | On a 4/12 roof |
|---|---|---|
| Asphalt shingles | 2 in 12 | Yes |
| Clay or concrete tile | 2 1/2 in 12 | Yes |
| Wood shingles or shakes | 3 in 12 | Yes |
| Metal roof shingles | 3 in 12 | Yes |
| Slate | 4 in 12 | Yes |
| Roll roofing, mineral surfaced | 1 in 12 | Yes |
| Standing seam metal | 1/4 in 12 | Yes |
| Membrane or built-up roofing | 1/4 in 12 | Yes |
| Metal panels with lapped seams | 3 in 12 | Yes |
This is where the code low slope rules end. From 4/12 up, asphalt shingles and clay or concrete tile need only one layer of underlayment, and slate is allowed for the first time, so every roofing type in the table can go on a 4/12 roof.
Underlayment and ice barrier at 4/12
At 4/12 one layer of underlayment is enough under shingles and tile.
Where the local code calls for an ice barrier along the eaves, it must reach at least 24 inches inside the outside wall. The extra 36 inch rule for steep roofs starts at 8/12.
| Overhang past the wall | Ice barrier reaches, measured up the slope |
|---|---|
| None | 25 in |
| 12 in | 38 in |
| 24 in | 51 in |
Attic space at 4/12
The code counts attic floor with at least 5 feet of headroom toward a room's size, and wants half of it to have 7 feet. Heights here run from the ceiling joists to a simple gable roof, before rafter and floor depth.
| House width | Ridge above the joists | Width with 5 ft of headroom | Width with 7 ft of headroom |
|---|---|---|---|
| 24 ft | 48' 0" | None | None |
| 28 ft | 56' 0" | None | None |
| 32 ft | 64' 0" | 2' 0" | None |
| 36 ft | 72' 0" | 6' 0" | None |
| 40 ft | 80' 0" | 10' 0" | None |
It takes a house about 42 feet wide for the ridge to reach 7 feet, so on an ordinary house this attic is storage or crawl space.
Working on a 4/12 roof
Most people can walk upright on a dry 4/12 roof without trouble, and loose tools and bundles stay put. That is a rule of thumb, and any roof is dangerous when wet or frosty.
OSHA counts a roof of 4 in 12 or less as low-slope, so roofing crews here may use a warning line with a safety monitor, as well as guardrails, nets or personal fall arrest. The steepest stair the code allows in a house, 7 3/4 inch risers on 10 inch treads, climbs at 37.8 degrees. This roof is 19.3 degrees gentler.
More about 4/12 roofs
OSHA draws its own line at the same number but puts 4/12 on the other side of it. A roof of 4 in 12 or less is a low-slope roof under OSHA, so 4/12 is the steepest roof where roofing crews may still use low-slope fall protection, such as a warning line paired with a safety monitor. At 5/12 those options end.
Nearby pitches
Compare with the 3/12 roof pitch and 5/12 roof pitch, or see every pitch in the chart on the roof pitch calculator. There is also a printable roof pitch chart that fits on one page.
Common questions
What is a 4/12 roof pitch in degrees?
18.43 degrees, which is a 33.3 percent slope.
What is the pitch multiplier for a 4/12 roof?
1.054. Multiply a level run or a flat area by it to get the sloped length or the roof area.
How long is a rafter on a 24 foot wide building at 4/12?
About 12' 7 13/16" from the ridge to the outside of the wall, before any overhang or ridge board deduction. The ridge sits 4' 0" above the top of the wall.
Can you put asphalt shingles on a 4/12 roof?
Yes. A 4/12 roof is above the 4 in 12 mark, so asphalt shingles go on with standard single underlayment.
Is a 4/12 roof walkable?
As a rule of thumb, roofers treat a 4/12 roof as walkable with care. Any roof is dangerous when wet.
Does a 4/12 roof need double underlayment?
No. The International Residential Code asks for double underlayment under shingles and tile only below 4 in 12. At 4/12 one layer is enough, though the shingle maker instructions can ask for more.
Can you put slate on a 4/12 roof?
Yes. 4/12 is the lowest pitch the code allows for slate.
Tools for this job
Each link opens an Amazon search for that item. As an Amazon Associate I earn from qualifying purchases.
- Speed square. Held against a rafter with a small level on top, it reads the pitch straight off its scale.
- Digital angle finder. Set it on a rafter or on the roof and it shows the angle in degrees.
- Level, 24 inch. Held level against a rafter, it lets you measure the rise at the 12 inch mark.
- Tape measure. Measures the rise, the run and the span.
Sources
- International Residential Code 2021, Chapter 9: roof drainage (R903) and roof coverings (R905)
- International Residential Code 2021, Chapter 3: room area and ceiling height (R304, R305) and stairs (R311.7)
- OSHA 29 CFR 1926.500: definitions of low-slope and steep roofs
- OSHA 29 CFR 1926.501: fall protection in construction
- HomeAdvisor: shingle roof replacement cost, with removal of the old roof
Facts on this page were last checked against these sources in October 2026.